                               Forward Annotation
                               ------------------

                          12:45 PM Sunday, May 03, 2020
        Job Name: E:\Compulab VX.2\FT-M2B-Rev.1.1\PCB\FT-M2B-Rev.1.1.pcb


Version:  01.01.00

     The PDBs listed in the project file will be searched to satisfy the parts
      requirements of the iCDB only for parts not already found in the
      Target PDB.

     The schematic source is a Keyin Netlist.
     

    2:  no valid page assigned previous to %%part/value - assuming page 1
   65:  no valid priority assigned previous to %%net - assuming priority 6
     Netlist has no syntax errors

     The Keyin Netlist has been read

     Target PDB Name: Work\Layout_Temp\PartsDB.pdb

     Number of Part Numbers: 26
          Part Numb: TP_SMT -> Vend Part: TP_SMT 
          Part Numb: 111S31000S -> Vend Part: 111S31000S 
          Part Numb: 123V5R004S -> Vend Part: 123V5R004S 
          Part Numb: 131D31540S -> Vend Part: 131D31540S 
          Part Numb: 141C32300I -> Vend Part: 141C32300I 
          Part Numb: 147A2R206S -> Vend Part: 147A2R206S 
          Part Numb: 151B10400S -> Vend Part: 151B10400S 
          Part Numb: 151B10600S -> Vend Part: 151B10600S 
          Part Numb: 151C10500S -> Vend Part: 151C10500S 
          Part Numb: 151C22400S -> Vend Part: 151C22400S 
          Part Numb: 151D10200S -> Vend Part: 151D10200S 
          Part Numb: 151K33000S -> Vend Part: 151K33000S 
          Part Numb: 161C1R001S -> Vend Part: 161C1R001S 
          Part Numb: 161C49R91S -> Vend Part: 161C49R91S 
          Part Numb: 161C00005S -> Vend Part: 161C00005S 
          Part Numb: 161C10011S -> Vend Part: 161C10011S 
          Part Numb: 161C10021S -> Vend Part: 161C10021S 
          Part Numb: 161C14031S -> Vend Part: 161C14031S 
          Part Numb: 161C30021S -> Vend Part: 161C30021S 
          Part Numb: 161C30131S -> Vend Part: 161C30131S 
          Part Numb: 161C44221S -> Vend Part: 161C44221S 
          Part Numb: 161C49901S -> Vend Part: 161C49901S 
          Part Numb: 182K06700S -> Vend Part: 182K06700S 
          Part Numb: 182K06702S -> Vend Part: 182K06702S 
          Part Numb: 190I01000S -> Vend Part: 190I01000S 
          Part Numb: 155068R00S -> Vend Part: 155068R00S 

     Number of Part Names: 0

     Number of Part Labels: 0




     46 nets were found containing 227 pins
     62 components were found

     Creating a formatted Schematic Netlist (LogFiles\SchematicNetlist.txt)...
     A formatted Schematic Netlist has been created.

     The Logic DataBase and the Schematic Design are now in sync.  Use
      Netload to bring the Component Design into sync.

     Logic Data has been successfully Compiled with no errors or warnings.
      Please proceed with your component Design.
                                     NetLoad
                                     -------

                          12:45 PM Sunday, May 03, 2020
        Job Name: E:\Compulab VX.2\FT-M2B-Rev.1.1\PCB\FT-M2B-Rev.1.1.pcb


Version:  02.11.12

	Netloading the Layout.  Unused components will be deleted.

	Unconnected pins will be set to net "(Net0)".

	Schematic reference designator changes will not be forward annotated.


    WARNING:  Adding PCB Net Name "$" to the NetPropsDB.

     Netload completed successfully with 1 warning(s).
     
     Back Annotating...

  Updating Logic Database...

     Version:  99.00.05

     Writing a list of routed plane pins to Logic\rtdplane.caf.

     Finished updating the Logic Database.

     Creating a formatted Schematic Netlist (LogFiles\AfterBakAnnoNetlist.txt)...
     A formatted Schematic Netlist has been created.

            Creating a new Keyin Netlist (E:\Compulab VX.2\FT-M2B-Rev.1.1\PCB\Logic\FT-M2B-1_1.kyn)
            from the Logic Database (Work\Layout_Temp\LogicDB.lgc)...
  A new Keyin Netlist has been generated.



                 Beginning Netload on the Layout Design.
           ---------------------------------------------------

Forward-Annotation on the Layout Design has been successfully completed.

There were 0 reassignments of nets.
There were 0 traces broken back.
There were 0 nets removed from the Layout Design.